Boston Scientific Corporation
opticross hd intravascular ultrasound ivus system ![]() Opticross Hd Intravascular Ultrasound Ivus System, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/hd+ivus/pmc13154088-39-7-5 Average 86 stars, based on 1 article reviews
opticross hd intravascular ultrasound ivus system - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
Boston Scientific Corporation
hd opticross 60 mhz ivus catheter ![]() Hd Opticross 60 Mhz Ivus Catheter, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/catheter+imaging+opticrosstm/pm41947029-39-8-14 Average 86 stars, based on 1 article reviews
hd opticross 60 mhz ivus catheter - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
Boston Scientific Corporation
fr opticross high definition hd ivus catheter ![]() Fr Opticross High Definition Hd Ivus Catheter, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/catheter+ivus/pm40891272-57-29-35 Average 86 stars, based on 1 article reviews
fr opticross high definition hd ivus catheter - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
Boston Scientific Corporation
intravascular ultrasound (ivus) opticross hd plus 60mhz coronary imaging catheter ![]() Intravascular Ultrasound (Ivus) Opticross Hd Plus 60mhz Coronary Imaging Catheter, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/opticross+hd/pmc12198647-30-8-17 Average 90 stars, based on 1 article reviews
intravascular ultrasound (ivus) opticross hd plus 60mhz coronary imaging catheter - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Boston Scientific Corporation
opticross hd intravascular ultrasound ivus catheter ![]() Opticross Hd Intravascular Ultrasound Ivus Catheter, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/balloon+catheter+coronary+dilatation+maverick2+%E2%80%A2/10__4244_slash_eij___d___24___01018-75-26-32 Average 86 stars, based on 1 article reviews
opticross hd intravascular ultrasound ivus catheter - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
ACIST Medical Systems
hd ivus opticross hd/ilab ![]() Hd Ivus Opticross Hd/Ilab, supplied by ACIST Medical Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/hd+ivus+opticross+hd+ilab/pmc12126068-139-6-11 Average 90 stars, based on 1 article reviews
hd ivus opticross hd/ilab - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Boston Scientific Corporation
5-f opticross hd-ivus catheter ![]() 5 F Opticross Hd Ivus Catheter, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/5+f+opticross+hd+ivus+catheter/pmc11911884-21-2-6 Average 90 stars, based on 1 article reviews
5-f opticross hd-ivus catheter - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Boston Scientific Corporation
ivus opticross hd 60 mhz ![]() Ivus Opticross Hd 60 Mhz, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/40+mhz+ivus+catheter+opticross/pmc11874252-30-19-24 Average 90 stars, based on 1 article reviews
ivus opticross hd 60 mhz - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
|
Boston Scientific Corporation
для виконання ivus використовується коронарний катетер для візуалізації opticross hd з частотою 60 мгц ![]() для виконання Ivus використовується коронарний катетер для візуалізації Opticross Hd з частотою 60 мгц, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hd+ivus+opticross+hd/hd+ivus/10__31928_slash_2664___4479___2024__6__5662-81-0-14 Average 86 stars, based on 1 article reviews
для виконання ivus використовується коронарний катетер для візуалізації opticross hd з частотою 60 мгц - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
Journal: JACC Case Reports
Article Title: Novel Use of Dual-Lumen Microcatheter for False Lumen Hematoma Decompression
doi: 10.1016/j.jaccas.2026.107511
Figure Lengend Snippet: Intravascular Ultrasound Images of True and False Lumen (A) Intravascular ultrasound located in the false lumen demonstrating the smaller true lumen. (B) Same still image with annotation of true and false lumens.
Article Snippet: Position was confirmed using a
Techniques:
Journal: JACC Case Reports
Article Title: Coronary Rupture Right After Intravascular Lithotripsy for Severely Calcified Coronary Lesion With C-CAT Sign
doi: 10.1016/j.jaccas.2025.103750
Figure Lengend Snippet: Intravascular Ultrasound Findings The white arrow indicates the significant stenosis at the diagonal branch bifurcation via coronary angiography. The white triangle indicates the calcified plaque and the C-type calcified and residual thin plaque sign (C-CAT sign) observed by intravascular ultrasound. In addition, the reference vessel diameter was sufficient for 3.0 mm.
Article Snippet: After the 1.5-mm semicompliant balloon dilatation, an intravascular
Techniques:
Journal: Journal of the Society for Cardiovascular Angiography & Interventions
Article Title: High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography: Lumen Size and Plaque Morphology
doi: 10.1016/j.jscai.2024.102520
Figure Lengend Snippet: Lumen diameters by high-definition intravascular ultrasound (HD IVUS), optical coherence tomography (OCT), and microcomputed tomography (μCT) across different silicone models. ( A ) 2.0 mm, ( B ) 2.5 mm, ( C ) 3.0 mm, ( D ) 3.5 mm, ( E ) 4.0 mm, ( F ) 4.5 mm, ( G ) 5.0 mm, and ( H ) 6.0 mm models. MLD, mean lumen diameter.
Article Snippet: All 3 of them used earlier
Techniques: Tomography
Journal: Journal of the Society for Cardiovascular Angiography & Interventions
Article Title: High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography: Lumen Size and Plaque Morphology
doi: 10.1016/j.jscai.2024.102520
Figure Lengend Snippet: Lumen areas by high-definition intravascular ultrasound (HD IVUS), optical coherence tomography (OCT), and microcomputed tomography (μCT) across different silicone models. ( A ) 2.0 mm, ( B ) 2.5 mm, ( C ) 3.0 mm, ( D ) 3.5 mm, ( E ) 4.0 mm, ( F ) 4.5 mm, ( G ) 5.0 mm, and ( H ) 6.0 mm models.
Article Snippet: All 3 of them used earlier
Techniques: Tomography
Journal: Journal of the Society for Cardiovascular Angiography & Interventions
Article Title: High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography: Lumen Size and Plaque Morphology
doi: 10.1016/j.jscai.2024.102520
Figure Lengend Snippet: Absolute and percentage lumen diameter and area differences of high-definition intravascular ultrasound (HD IVUS) and optical coherence tomography (OCT) vs microcomputed tomography (μCT) in silicone models. ( A ) Absolute difference of HD IVUS and OCT compared to μCT of mean lumen diameter (MLD); ( B ) absolute difference of HD IVUS and OCT compared to μCT of lumen area; ( C ) percentage difference of HD IVUS and OCT compared to μCT of MLD; ( D ) percentage difference of HD IVUS and OCT compared to μCT of lumen area.
Article Snippet: All 3 of them used earlier
Techniques: Tomography
Journal: Journal of the Society for Cardiovascular Angiography & Interventions
Article Title: High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography: Lumen Size and Plaque Morphology
doi: 10.1016/j.jscai.2024.102520
Figure Lengend Snippet: Bland Altman analysis of high-definition intravascular ultrasound (HD IVUS), optical coherence tomography (OCT) vs microcomputed tomography (μCT) in silicone models. ( A ) HD IVUS compared with μCT of mean lumen diameter (MLD); ( B ) HD IVUS compared with μCT of lumen area; ( C ) OCT compared with μCT of MLD; ( D ) OCT compared with μCT of lumen area.
Article Snippet: All 3 of them used earlier
Techniques: Tomography
Journal: Journal of the Society for Cardiovascular Angiography & Interventions
Article Title: High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography: Lumen Size and Plaque Morphology
doi: 10.1016/j.jscai.2024.102520
Figure Lengend Snippet: Bland Altman analysis of high-definition intravascular ultrasound (HD IVUS) compared with optical coherence tomography (OCT) of mean lumen diameter (MLD) and lumen area for coronary arteries. ( A ) HD IVUS (AVVIGO+) compared with OCT (Ultreon 2.0) of MLD; ( B ) HD IVUS (AVVIGO+) compared with OCT (Ultreon 2.0) of lumen area; ( C ) HD IVUS (POLARIS) compared with OCT (AptiVue) of MLD; ( D ) HD IVUS (POLARIS) compared with OCT (AptiVue) of lumen area.
Article Snippet: All 3 of them used earlier
Techniques: Tomography
Journal: Journal of the Society for Cardiovascular Angiography & Interventions
Article Title: High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography: Lumen Size and Plaque Morphology
doi: 10.1016/j.jscai.2024.102520
Figure Lengend Snippet: Fine wall and plaque structures on intravascular ultrasound (IVUS) vs optical coherence tomography (OCT). ( A ) Thin-cap fibroatheroma on OCT; ( B ) thin cap fibroatheroma on IVUS; ( C ) ruptured and healed fibroatheroma on OCT; ( D ) ruptured and healed fibroatheroma on IVUS; ( E ) thick cap fibroatheroma on OCT; ( F ) thick cap fibroatheroma on IVUS; ( G ) fibrocalcific atheroma on OCT; ( H ) fibrocalcific atheroma on IVUS; ( I ) spontaneous coronary artery dissection on OCT; ( J ) spontaneous coronary artery dissection on IVUS; ( K ) stent strut on OCT; ( L ) stent strut on IVUS. FC, fibrous cap; LC, lipid core; NC, necrotic core.
Article Snippet: All 3 of them used earlier
Techniques: Tomography, Dissection
Journal: Journal of the Society for Cardiovascular Angiography & Interventions
Article Title: High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography: Lumen Size and Plaque Morphology
doi: 10.1016/j.jscai.2024.102520
Figure Lengend Snippet: Comparison of lumen size and plaque morphology between high-definition intravascular ultrasound (HD IVUS) and optical coherence tomography (OCT). μCT, microcomputed tomography; MLD, mean lumen diameter.
Article Snippet: All 3 of them used earlier
Techniques: Comparison, Tomography
Journal: Catheterization and Cardiovascular Interventions
Article Title: Enhanced Efficiency of Sequential Cutting Balloon Angioplasty in Calcified Coronary Artery Disease: The RODIN‐CUT Technique
doi: 10.1002/ccd.31387
Figure Lengend Snippet: Images Location (A) Top: 7 Fr guiding catheter with an IVUS catheter proximal to the cutting balloon that is placed at the level of the lesion. This setup allows for an almost immediate interchange of treatment and diagnostic and optimizes the effect of the therapy. (B–F) Center: The effect of multiplying the cutting balloon inflations. The blue and the green dots represent the two guidewires. (G) Bottom Left: The “Cutting” effect with separation of the plaque into multiple smaller fragments: see Red Triangle. (H) Bottom Right: The “Chiseling” indicates superficial fissures related to multiple CB inflations. [Color figure can be viewed at wileyonlinelibrary.com ]
Article Snippet: The RODIN CUT is a systematic approach designed to assess the effects of the CB on calcified plaques, using
Techniques: Diagnostic Assay